2. Function

During the filtration phase, the baffle plate is forced upwards by the flow. Dust particles are separated on the cartridge surface and a filter cake forms.
The cleaning pulse forces the baffle plate downwards and moves the cartridge out of the filtered fluid flow. At the same time, the rotating wing element is set in motion by the nozzle holes and the filter cake is
detached by the fine pulsed air jets and the simultaneous vibratory movement in the cartridge pleats.

.
Filtration phase Cleaning phase

 

3. Technical data

 

Cleaning unit for Quick-Lock dust cartridges with an outside diameter of 328 mm.

Materials: Aluminium, galvanized steel, polypropylene
Operating temperature: -20 °C to 50 °C
Differential pressure via filter plate: max. 30 mbar
Cleaning
medium:
.
Oil, dust and condensate-free compressed air
at operating temperature
Compressed air connection: G¾ male
Compressed air: 3 bar to 4 bar (max. 4.2 bar)
Pulse duration: 0.5 s to 3 s (standard 1.5 s)

.

Compressed air consumption
Type designation Capacity of pressure vessel [l] Compressed air consumption per cleaning impuls [l] (fad)
RLK-3206 ROH

16

Approx. 50

RLK-3210 ROH

32

Approx. 80

RLK-3212 ROH

32

Approx. 90


Technical data is subject to change without notice!